Fitness-for-Service (FFS), engineered into the platform.

API 579 fitness-for-service assessment, on platform. Level 1 and Level 2 covered. Parts 3, 4, 5, and 9 - brittle fracture susceptibility, general metal loss, local thinning, and crack-like flaws. Configurable workflow, structured input, defensible calculation output. The assessment that tells you whether to keep the asset in service - encoded, audited, and ready for the next reassessment.

Fitness-for-Service (FFS)

What FFS does

From damage finding to engineering decision.

An inspector finds a thinned area on a vessel shell. A crack-like flaw on a piping weld. A region of corrosion on a tank bottom. The next question is the most expensive question in integrity engineering: is the asset still fit for service? FFS answers it on the platform - with the API 579 calculation, the operating conditions, the material data, and the engineer's judgement, all in one place. The result: a decision you can defend to a regulator.

code_xml
API 579-1 / ASME FFS-1

Fitness-for-Service. The recommended practice that governs FFS assessment.

api
Level 1 assessment

conservative, screening-level evaluation. Used to determine whether further analysis is needed.

api
Level 2 assessment

more detailed evaluation using configurable methodology and refined inputs.

api
Part 3 - Brittle Fracture

susceptibility assessment for low-temperature service and material toughness concerns.

api
Part 4 - General Metal Loss

assessment of broad areas of uniform thinning.

api
Part 5 - Local Metal Loss

assessment of localized thinning, pitting, and groove-type damage.

api
Part 9 - Crack-Like Flaws

fracture mechanics-based assessment of cracks and crack-like indications.

Assessment levels encoded in AsInt Edge FFS

Capability levels and bundling

FFS capability bundles - choose the parts your assessment program requires.

Parts 4 and 5

Metal Loss

Operators dealing primarily with corrosion and thinning. Most common starting point.

Parts 3 and 9

Fracture and Crack

Operators with crack indications, brittle fracture concerns, or cold-service equipment.

Any 3 parts (your choice)

Custom Configuration

Operators with a specific mix of damage types not covered by the standard bundles.

All four parts: 3, 4, 5, 9

Ultra (All Parts)

Engineering services firms, large integrity teams, or any operator with the full range of FFS use cases.

Capability Breakdown

Make Informed Run, Repair, or Replace Decisions Assess, Validate, Approve, and Operate.

Empower asset integrity teams with standards-based Fitness-for-Service assessments, automated screening, advanced engineering calculations, asset-integrated workflows, and controlled approval processes to support safe and reliable equipment operation.

API 579-1 / ASME FFS-1 Compliant Assessments

Perform Industry-Recognized Fitness-for-Service Evaluations

Execute standardized Fitness-for-Service assessments using methodologies aligned with API 579-1/ASME FFS-1 to determine whether equipment can continue operating safely and reliably.

Business Value
Improve confidence in integrity decisions while ensuring assessments are performed using recognized industry standards and best practices.

API 579-1 / ASME FFS-1 Compliant Assessments

Intelligent Assessment Pre-Screener

Quickly Determine Assessment Applicability

Reduce engineering effort through an integrated pre-screener that evaluates whether a particular damage mechanism, component type, or assessment procedure is applicable before detailed calculations begin.

Business Value
Save engineering time, improve efficiency, and ensure the correct assessment methodology is selected from the start.

Intelligent Assessment Pre-Screener

Multi-Level Fitness-for-Service Analysis

Progress from Screening to Detailed Engineering Evaluation

Support both Level 1 and Level 2 Fitness-for-Service assessments, enabling organizations to perform increasingly detailed evaluations based on equipment condition and assessment requirements.

Business Value
Enable consistent, defensible integrity assessments while helping engineers determine equipment fitness with the appropriate level of analysis.

Multi-Level Fitness-for-Service Analysis

Integrated Asset Data Management

Eliminate Manual Data Entry and Improve Accuracy

Seamlessly integrate with the Asset-Centric Workbench to automatically retrieve equipment, component, and design information required for Fitness-for-Service evaluations.

Business Value
Accelerate assessment preparation, reduce transcription errors, and improve productivity by leveraging existing asset information.

Integrated Asset Data Management

Review, Approval & Governance Workflow

Streamline Engineering Collaboration and Assessment Approvals

Manage assessment reviews through a structured workflow that enables collaboration among engineers, reviewers, and approvers while maintaining complete traceability.

Business Value
Ensure engineering integrity, improve accountability, and accelerate assessment approvals through a transparent and controlled review process.

Review, Approval & Governance Workflow

Who Uses FFS

For the engineers running the assessment and the stakeholders, the decision belongs to.

Daily Users

Materials Engineers, Integrity Engineers & Principal Engineers

You run the assessment, own the methodology, and sign off on the output. Materials engineers characterize the damage mechanism and select the appropriate API 579-1 part. Integrity engineers structure the inputs - component geometry, operating conditions, thickness data from CML - and run the Level 1 or Level 2 evaluation. Principal engineers review the acceptability determination and the margin behind it before the assessment is published. All three roles work on the same structured record - inputs, calculations, and engineering judgement captured in one place, not assembled across separate files before a decision is made.

Materials Engineers, Integrity Engineers & Principal Engineers

Stakeholders

Plant Managers, Regulators, Insurers & Engineering Services Firms

The FFS assessment is the basis for the most consequential decision in an integrity programme - keep the asset in service or remove it. Plant managers use the acceptability of determination and remaining life output to make that call with a documented margin behind it, not an informal engineering opinion. Regulators and insurers require the same thing: a structured assessment, traceable to a recognized Code, with every input and calculation on record. Engineering services firms have a different relationship with FFS - the assessment is a billable deliverable, and AsInt Edge is the platform it's delivered on. Client work runs in isolated project folders; assessment reports are generated directly from the workflow, and the audit trail that comes with every assessment is part of what the firm hands over.

Plant Managers, Regulators, Insurers & Engineering Services Firms

Ready to start?

No annual contract. Cancel anytime.